Custom cutting guides (CCGs; sometimes called patient-specific instrumentation [PSI]) in total knee arthroplasty (TKA) use preoperative three-dimensional imaging to fabricate cutting blocks specific to a patient's native anatomy.
The purposes of this study were to determine if CCGs (1) improve clinical outcomes as measured by UCLA activity, SF-12, and Oxford knee scores; and (2) coronal mechanical alignment versus standard alignment guides.
At a mean followup of greater than 2 years, CCGs fail to demonstrate any advantages in validated knee outcome measure scores or coronal alignment as measured by CT scan versus the use of standard instrumentation in TKA. The clinical benefit of CCGs must be proven before continued implementation of this technology.
Level of evidence: Level III, retrospective controlled study. Copyright remains with the authors and publisher.
Custom cutting guides (CCGs; sometimes called patient-specific instrumentation [PSI]) in total knee arthroplasty (TKA) use preoperative three-dimensional imaging to fabricate cutting blocks specific to a patient's native anatomy.
The purposes of this study were to determine if CCGs (1) improve clinical outcomes as measured by UCLA activity, SF-12, and Oxford knee scores; and (2) coronal mechanical alignment versus standard alignment guides.
At a mean followup of greater than 2 years, CCGs fail to demonstrate any advantages in validated knee outcome measure scores or coronal alignment as measured by CT scan versus the use of standard instrumentation in TKA. The clinical benefit of CCGs must be proven before continued implementation of this technology.
Level of evidence: Level III, retrospective controlled study. Copyright remains with the authors and publisher.