Notching of the anterior femoral cortex during total knee arthroplasty has been implicated as a cause of subsequent periprosthetic supracondylar femoral fracture. However, other than observational clinical data, no reliable association between these events has been established, to our knowledge. The purpose of the present study was to investigate the biomechanical effects of notching of the anterior femoral cortex.
Biomechanical testing demonstrated that notching of the anterior femoral cortex significantly lessens the load to failure following total knee arthroplasty and influences the subsequent fracture pattern. These effects are manifested in different ways under the two loading conditions: the fracture pattern is altered under bending load, and there is a greater quantitative decrease in load to failure with torsional loading.
Clinical Relevance: Weakening of the femur by notching of the anterior cortex after total knee arthroplasty may warrant alteration in the customary postoperative regimen for these patients. Manipulation of a total knee replacement with a notched anterior femoral cortex should probably be avoided.
Copyright remains with the authors and publisher.
Notching of the anterior femoral cortex during total knee arthroplasty has been implicated as a cause of subsequent periprosthetic supracondylar femoral fracture. However, other than observational clinical data, no reliable association between these events has been established, to our knowledge. The purpose of the present study was to investigate the biomechanical effects of notching of the anterior femoral cortex.
Biomechanical testing demonstrated that notching of the anterior femoral cortex significantly lessens the load to failure following total knee arthroplasty and influences the subsequent fracture pattern. These effects are manifested in different ways under the two loading conditions: the fracture pattern is altered under bending load, and there is a greater quantitative decrease in load to failure with torsional loading.
Clinical Relevance: Weakening of the femur by notching of the anterior cortex after total knee arthroplasty may warrant alteration in the customary postoperative regimen for these patients. Manipulation of a total knee replacement with a notched anterior femoral cortex should probably be avoided.
Copyright remains with the authors and publisher.