Reports in the literature indicate that implant placement is more accurate with robotic-assisted unicompartmental knee arthroplasty (UKA); however, these studies have not always accounted for surgeon experience. The purpose of the present study was to compare the accuracy of tibial component alignment in UKA between an experienced high-volume surgeon and the published data on robotic-assisted surgery.
Accurate implant alignment is important in UKA. In this study, an experienced surgeon achieved or exceeded robotic accuracy of tibial implant alignment in UKA. However, the relationship between implant position and patient outcomes is unknown, and a consensus on ideal surgical targets for optimal implant survivorship has yet to be established.
Level of evidence: Therapeutic Level IV . Copyright remains with the authors and publisher.
Reports in the literature indicate that implant placement is more accurate with robotic-assisted unicompartmental knee arthroplasty (UKA); however, these studies have not always accounted for surgeon experience. The purpose of the present study was to compare the accuracy of tibial component alignment in UKA between an experienced high-volume surgeon and the published data on robotic-assisted surgery.
Accurate implant alignment is important in UKA. In this study, an experienced surgeon achieved or exceeded robotic accuracy of tibial implant alignment in UKA. However, the relationship between implant position and patient outcomes is unknown, and a consensus on ideal surgical targets for optimal implant survivorship has yet to be established.
Level of evidence: Therapeutic Level IV . Copyright remains with the authors and publisher.