Glenoid lateralization has been shown to be the most imortant factor in maximizing passive range of motion and shoulder stability while preventing scapular impingement and notching. We aimed to evaluate mid- to long-term functional and radiologic outcomes after bony increased-offset-reverse shoulder arthroplasty (BIO-RSA) using a Grammont-style (medialized) humeral implant.
BIO-RSA is a safe and effective technique to lateralize the glenoid, providing consistent bone graft healing, excellent functional outcomes, a low revision rate, and a high rate of patient satisfaction. Thin patients (with a low body mass index) and glenosphere malposition (with persistent superior inclination and/or insufficient lowering of the baseplate and sphere) are associated with higher risk of scapular notching.Our data confirm the importance of implanting the baseplate with a neutral inclination (reverse shoulder arthroplasty angle < 5°) and with sufficient glenosphere inferior overhang (>5 mm) in preventing scapular notching. The use of a less medialized humeral implant (135° or 145° inclined) and smaller (25-mm) baseplate (when using a small, 36-mm sphere) should allow reduction in the incidence of scapular notching.
Copyright remains with the authors and publisher.
Glenoid lateralization has been shown to be the most imortant factor in maximizing passive range of motion and shoulder stability while preventing scapular impingement and notching. We aimed to evaluate mid- to long-term functional and radiologic outcomes after bony increased-offset-reverse shoulder arthroplasty (BIO-RSA) using a Grammont-style (medialized) humeral implant.
BIO-RSA is a safe and effective technique to lateralize the glenoid, providing consistent bone graft healing, excellent functional outcomes, a low revision rate, and a high rate of patient satisfaction. Thin patients (with a low body mass index) and glenosphere malposition (with persistent superior inclination and/or insufficient lowering of the baseplate and sphere) are associated with higher risk of scapular notching.Our data confirm the importance of implanting the baseplate with a neutral inclination (reverse shoulder arthroplasty angle < 5°) and with sufficient glenosphere inferior overhang (>5 mm) in preventing scapular notching. The use of a less medialized humeral implant (135° or 145° inclined) and smaller (25-mm) baseplate (when using a small, 36-mm sphere) should allow reduction in the incidence of scapular notching.
Copyright remains with the authors and publisher.